Model No.:  WNS0.5

Product Description Model NO.: WNS0.5 Fuel: Oil or Gas Fired Structure: Fire Tube Water Circulation: Natural Circulation Pressure: Pressure Burning Style: Chamber Combustion Boiler Rated Evaporation: 500kg/H Transport Package: Wooden Frame Origin: Yangzhou, China Function: Steam Boilers Installation: Packaged Boiler Media: Steam and Water Drum Placement: Horizontal Boiler Manufacturing Level: B Usage: Industrial Trademark: anxin boiler Specification: WNS Horizontal Industry Oil (Gas) Condensing Bearing Steam Boiler Wns0.5
Characteristic Recommendation:
1.Adopt the structure of three pass wetback, smoke pipes are symmetrically distributed with the center of furnace axle, which can improve the stress distribution of the pipe plate.  The combustion chamber of the wetback structure is completely dipping into water, with good cooling condition, the back pipe plate is not influenced by the high temperature smoke, which is with long lifetime.
2.The application of corrugated furnace has not only increased the heating surface, but also relieve the possible injury to the combustion chamber due to expanding by heat and contraction by cold so as to improve its strength.
3.The fully combustion of the large furnace enables the sufficient saving of fuel.
4.Large steam space enables a low speed for the steam when breaking away from the water surface, and there is built-in steam and water splitting device, enabling the output of high quality steam steadily.
5.Adopt the threaded pipe to enforce the heat exchanging effect, which has promoted the heating efficiency.
6.Apply the advanced digital control technology, capable of monitoring and controlling the combustion process in remote accurately.
7.With high automation degree, with various kinds of protection, realizing the automatic control of water level pressure etc. Condensation Heat Exchanger can be added in the smoke outlet to decrease the smoke discharging temperature, absorb the sensible and latent heat in the smoke, improve the heating efficiency (up to 95%).
Specification:
(Item) WNS0.5 WNS0.75 WNS1 WNS1.5 WNS2 WNS3
-Y(Q) -Y(Q) -Y(Q) -Y(Q) -Y(Q) -Y(Q)
(Rated evaporation) Kg/h 500 750 1000 1500 2000 3000
(Working pressure) Mpa 0.7 1.0 0.7 0.7 1.0 1.0 1.25 1.0 1.25 1.0 1.25
(Working temperature) ºC 171 184 171 171 184 184 193 184 193 184 193
(Feed water temperature) ºC 20
(Efficiency) % 94.39 94.19 94.61 95.26 95.06 94.46 94.35 96.01 95.91 96 96
(Water capacity ) L 1643 1643 2215 2410 3200 3650 3650 5000 5000 5500 5500
(Water outlet) mm 50 50 50 50 50 65 65 65 65 80 80
(Feed water inlet) mm 40 40 40 40 40 40 40 40 40 40 40
(Drain valve) mm 40 40 40 40 40 50 50 50 50 50 50
(Safety valve) mm 40 40 40×2 40×2 40×2 40×2 40×2 40×2 40×2 50×2 50×2
(Chimney) mm 219 280 280 330 330 400
(Size) (Length) mm 3100 3100 3200 3200 3400 3605 3605 4150 4150 4500 4500
(Width) mm 2150 2150 1900 1860 1900 1850 1850 2200 2200 2150 2150
(Height) mm 1870 1870 2160 2226 2250 2200 2200 2500 2500 3000 3000
(Transport weight) Kg 3000 3200 3880 4800 4960 5940 6230 7400 7860 10200 10800
(Size of base) mm 1000 1000 1050 1150 1150 1200 1200 1300 1300 1400 1400
mm 2000 2000 2100 2800 2800 3000 3000 3350 3350 3930 3930
(Fuel consumption) (Light oil) Kg/h 33.06 33.27 49.6 64.76 71 101.1 101.1 129 142 210 210
(L.N.G) Nm3/h 40.11 40.37 60.2 78.59 83.6 122.3 122.3 157 167 250 250
(C.G) Nm3/h 81.6 82.2 128.1 164.2 174.7 259.9 259.9 333.6 354.8 531.2 531.2
 
(Item) WNS4 WNS6 WNS8 WNS10 WNS12 WNS15 WNS20
-Y(Q) -Y(Q) -Y(Q) -Y(Q) -Y(Q) -Y(Q) -Y(Q)
(Rated evaporation) Kg/h 4000 6000 8000 10000 12000 15000 20000
(Working pressure) Mpa 1.0 1.25 1.25 1.6 1.25 1.6 1.25 1.6 1.25 1.25 1.25
(Working temperature) ºC 184 193 193 204 193 204 193 204 193 193 193
(Feed water temperature) ºC 20 104
(Efficiency) % 96.5 96.5 96.58 96.58 96.6 96.6 97 97 96.3 96.4 96.2
(Water capacity ) L 8900 8900 10300 10300 14800 14800 17000 17000 21000 28700 31700
(Water outlet) mm 100 100 125 125 125 125 150 150 150 200 200
(Feed water inlet) mm 40 40 40 40 40 40 40 40 50 65 80
(Drain valve) mm 50 50 50×2 50×2 50×2 50×2 50×2 50×2 50×3 50×3 50×3
(Safety valve) mm 50×2 50×2 65×2 65×2 65×2 65×2 80×2 80×2 80×2 100×2 100×2
(Chimney) mm 450 600 650 750 900 1000 1200
(Size) (Length) mm 5250 5250 6200 6200 6820 6820 7300 7300 7800 8300 8700
(Width) mm 2300 2300 2500 2500 2840 2840 3350 3350 3350 3400 3700
(Height) mm 2750 2750 3100 3100 3200 3200 3450 3450 3450 3800 3800
(Transport weight) Kg 11720 12500 18300 19500 22610 23200 28800 30150 31000 40000 44000
(Size of base) mm 1600 1600 2000 2000 2100 2100 2300 2300 2500 2500 2800
mm 4250 4250 5770 5770 6250 6250 6540 6540 6700 7000 7200
(Fuel consumption) (Light oil) Kg/h 275.6 275.6 387.75 337.4 451.5 451.5 606 606 714 835 1243
(L.N.G) Nm3/h 332.4 332.4 470 407.12 543.6 543.6 723 723 860 1006 1448
(C.G) Nm3/h 706.35 706.35 998.8 955.2 1275 1275 1536.4 1536.4 1900 2363 3160

 